Yuma, AZ28 posts · joined Nov 2025Reflection 297RSTS · Ram 3500
my Reflection came with a residential fridge, the big double door kind that looks like a house fridge, instead of the old propane absorption type. i love it in the campground on shore power, it is cold and it holds a lot. the question is the travel day.
a residential fridge runs on 120 volt only, so on the road it lives off the inverter pulling from the house batteries. i have two group 31 AGM batteries and a 1,000 watt inverter the factory put in. on a short hop it is fine. but i do the Yuma to Montana run and back twice a year, and a 10 or 12 hour travel day with the fridge cycling off the batteries the whole time worries me, especially the overnight stop at a Walmart with no hookup.
so: how much battery do i actually need to run a residential fridge for a long travel day plus an overnight, do i need to move to lithium, and does the truck charge the house batteries enough on the road through the 7 pin to keep up. anybody doing the long hauls with a residential fridge, i want your real numbers, not the brochure.
Glenn P.Moderator#2
Sierra Vista, AZ16 posts · joined Nov 2025Solitude 310GK · Ram 3500 dually · B&W Companion
real numbers. a residential RV fridge pulls something like 1 to 1.5 amps at 120 volt when the compressor runs, and it does not run constantly, it cycles. over a day it averages out to roughly 1,000 to 1,400 watt hours, call it a bit over 100 amp hours at 12 volt once you count inverter losses. your two group 31 AGM batteries are about 200 amp hours total and you only want to pull an AGM down to 50 percent, so you have about 100 usable amp hours. that is why a travel day is right at the edge for you and an overnight with no sun and no shore power will have you waking up to a dead bank.
two ways people fix it. one, go lithium. the same physical space in lithium gives you 2 to 3 times the usable capacity because you can run it down to near empty without hurting it, and it takes a charge much faster. two, the truck. a stock 7 pin charge wire is thin and long and it trickles maybe 10 or 20 amps to the trailer batteries by the time it gets back there, which does not keep up with a residential fridge plus everything else. people who tow all day either upsize that charge line, add a DC to DC charger in the trailer, or put a bit of solar on the roof. you probably want the lithium and the DC to DC charger together if you are doing Yuma to Montana.
and size the inverter for the startup surge, not the running watts. a fridge compressor pulls a big spike for a fraction of a second when it kicks on, so a soft start helps and a 1,000 watt inverter is really the floor for a residential unit.
montana_high_countrySnowbird#3
Rapid City, SD26 posts · joined Nov 2025Montana High Country 331RL · Ford F-350 SRW
i did exactly this swap on the Montana last spring. went from the two AGM group 31s to a pair of 100 amp hour lithium and added a 40 amp DC to DC charger wired off the truck. now the fridge runs all travel day and the truck actually puts a real charge back in while i drive instead of the trickle the 7 pin was giving me. overnight at a rest area with the fridge going is a non event, i wake up at like 70 percent.
cost me more than i wanted, the lithium and the charger and the wiring ran close to 1,400 dollars doing it myself. but i was replacing dying AGMs anyway so the real extra over just buying new AGMs was less. if your AGMs are still healthy i would not rip them out tomorrow, i would add the DC to DC charger first and see if that alone gets you through, it is the cheaper half of the fix.
fulltime_since_juneFull-timer#4
Sioux Falls, SD64 posts · joined Nov 2025Cedar Creek 34RL2 · Chevy Silverado 3500
i will give the counterpoint since everybody is pushing lithium. i kept the old absorption fridge in my Cedar Creek on purpose. it runs on propane on travel days and in the cold, uses almost no electricity, and i never think about the batteries for the fridge at all. it does not hold as even a temperature and it hates being parked unlevel, and it is slower to cool, but for cold weather full-timing it is the simpler animal.
the one place the residential wins hard for me would be summer in the desert, an absorption fridge struggles to keep up when it is 110 outside and the residential just keeps cold. so it is a real tradeoff and not a clear winner. for the snowbird who parks in Arizona heat, residential plus lithium makes sense. for a northern full-timer the propane absorption is one less thing to feed.
whichever you run, check what your specific floorplan left the factory with before you assume, the manufacturer lists it by model on their site. mine is a Forest River brand and the fridge type is right in the specs at forestriverinc.com, because the same floorplan came both ways some years.
andersen_hitch_userWeekender#5
Green Bay, WI19 posts · joined Nov 2025Forest River Sandpiper 321RL · Ford F-250 short bed
one safety note nobody has said. if you run the residential fridge off the inverter on travel days, make sure the inverter is actually wired to only the fridge circuit and not back-feeding the whole panel, and label the switch. my buddy left his inverter on, parked, and drained his bank flat overnight because the inverter was also powering a couple of outlets with phone chargers and a coffee maker someone left plugged in. the fridge was innocent, the coffee maker killed the batteries.
also weigh the lithium change if you are tight on pin or cargo. two lithium batteries are lighter than the two AGMs they replace, so that one actually helps your weight, which is a nice change for a mod that usually adds pounds.
desert_snowbirdOPSnowbird#6
Yuma, AZ28 posts · joined Nov 2025Reflection 297RSTS · Ram 3500
did the cheaper half first like montana_high_country said. added a 40 amp DC to DC charger off the truck and left the two AGMs for now. that alone changed the travel day completely, the truck is actually feeding the bank 40 amps while i drive instead of the dribble the 7 pin was doing, so i roll into the overnight stop near full instead of half.
the overnight with no engine running is still the weak spot on the AGMs, i dropped to about 55 percent by morning on a cold night with the fridge cycling. so lithium is coming next year, but for 300 dollars and an afternoon the DC to DC charger got me most of the way there and i can make the Yuma run this winter without sweating it. appreciate the real numbers, this is exactly the stuff the dealer could not tell me.
Log in to reply. No account yet? Ask a mod, it takes a day or two.